Skip to main content
WITTYWRITER / DISCOVER

What are you curious about?

Search all published articles and guides.

Ctrl K to open · Esc to close. Recent visits stay only in this browser.

Batch Cooling Calculator

Unsteady-State Heat Transfer Analysis (Well‑Mixed Batch + Constant U·A)

1. Batch Properties

Preset fills Cp and density. Verify at operating temp.
kg
kJ/kg·K
kg/m³
kW

2. Cooling Target

°C
°C
Optional: Latent Load
kJ/kg
kg

3. Cooling System

°C
°C
kJ/kg·K
kg/m³
Optional: Heat Transfer Coeff (U)
W/m²K
m²
-
min

Cooling Performance

--
Cooling Time
--
Peak Duty
--
Avg Duty
Temperature Profile (Exponential Decay)

Detailed Analysis

Total Heat Removed --
Sensible Heat --
Latent Heat --
Heat Generated --
Effective UA (F·U·A) --
Rep. Coolant Temp --
Steady State Tss --
Est. Coolant Flow --
Required UA (Design) --
Note: Flow estimate based on Average Duty and Coolant ΔT.

Technical Notes

Variable Definitions

  • M: batch mass (kg).
  • Cp: batch specific heat (kJ/kg·K).
  • MCp: thermal capacitance (kJ/K) = M·Cp.
  • T0, Tf: initial and target batch temperatures (°C).
  • Tc: representative coolant temperature (°C). This tool uses (Tc_in + Tc_out)/2.
  • q̇gen: internal heat generation (kW).
  • U: overall heat transfer coefficient (W/m²·K).
  • A: heat transfer area (m²).
  • F: effectiveness/correction factor (–).
  • UA: effective conductance (kW/K) = (U/1000)·A·F.
  • Tss: steady-state temperature where cooling equals heat generation.

Formulas / Logic

  • Well-mixed batch model: MCp·dT/dt = −UA·(T − Tc) + q̇gen.
  • Steady state: Tss = Tc + q̇gen/UA.
  • Temperature profile: T(t)=Tss+(T0−Tss)·exp(−UA·t/MCp).
  • Cooling time to target: t = (MCp/UA)·ln[(T0−Tss)/(Tf−Tss)].
  • Sensible heat removed: Qsens = MCp·(T0−Tf) (kJ).
  • Latent heat (optional): Qlat = mlat·hlat (kJ).
  • Heat generated: Qgen=q̇gen·t (kJ, with kW·s → kJ).
  • Average duty: Q̇avg≈(Qsens+Qlat)/t + q̇gen.
  • Coolant flow estimate: ṁc=Q̇avg/(Cp_c·ΔT_c) (kg/s).
Model corresponds to a lumped-capacitance batch (perfect mixing) with constant UA and constant coolant temperature represented by Tc_mean. Use as a screening/design tool.

Assumptions / Notes

  • Batch is well mixed (uniform temperature). If stratified, actual time may differ.
  • UA is constant. In reality, U can vary with viscosity, fouling, agitation, and coolant flow regime.
  • Coolant temperature is represented by mean of inlet/outlet (valid for small ΔT or roughly constant overall conditions).
  • Feasibility requires Tf > Tss. If heat generation is high, target may be unreachable without higher UA or lower coolant temperature.
  • Latent heat is treated as a lumped load added to total heat removed; it does not change the exponential profile.

Standards / References

  • Standard unsteady-state energy balance for well-mixed tanks (lumped parameter heat transfer).
  • Heat transfer coefficient ranges are engineering screening values; confirm with process/mechanical design standards and vendor data.
  • For detailed design, consider transient simulation or rigorous exchanger/jacket models if required by project standards.
🍪 We use cookies to improve your experience. Learn more